User Guide: FAAST Fire Alarm Aspiration Sensing Technology® Networking
32
Server Requirements
The mail server will accept messages from the FAAST detector and attempt to relay them to the specified recipients. This server must
meet the following requirements:
Accept and deliver messages from the e-mail address specified in the Sender Account field.
Accept and relay SMTP messages from port 25 without requiring authentication.
Have connectivity and DNS service to networks (such as the Internet) where recipient mail servers reside.
E-mail Client Requirements
Once connectivity to the mail server is established, the integrated SMTP client will communicate with the server to deliver alarm and
fault e-mail notifications. For the client to work properly, the following are required:
The Sender Account field is used to populate the SMTP “From” field and specifies where an e-mail message originates. This
field should be populated with an e-mail address specifically reserved for the detector. An e-mail account may need to be cre-
ated and added to the mail server by the server administrator.
Up to 6 recipient e-mail addresses and desired notifications must be configured.
E-mail Client Conguration
The integral SMTP client is configured using the PipeIQ software. Before attempting to configure the e-mail client, the IP configuration
of the detector should be completed and network connectivity verified. For instructions, see the TCP/IP Connectivity section earlier
in this guide.
1. Start the PipeIQ software application.
2. Open the project for it using File -> Open.
3. Double-click the desired device to open the Configuration window.