BEFORE INSTALLING
This information is included as a quick reference installation
guide. Refer to the appropriate control panel installation manual
for detailed system information. If the modules will be installed in
an existing operational system, inform the operator and local au-
thority that the system will be temporarily out of service. Discon-
nect the power to the control panel before installing the modules.
This system contains static sensitive components. Always ground
yourself with a proper wrist strap before handling any circuits so
that static charges are removed from the body. The module hous-
ing should also be grounded.
NOTICE: This manual should be left with the owner/user of
this equipment.
D500-49-00 1 I56-1799-005
INSTALLATION AND MAINTENANCE INSTRUCTIONS
CZ-6 Six Zone Interface Module
SPECIFICATIONS
Normal Operating Voltage: 15-32 VDC
Stand-By Current: 2 mA
Alarm Current: 40 mA (assumes all six LEDs solid on)
Temperature Range: 32°F to 120°F (0°C to 49°C)
Humidity: 10 to 93% Non-condensing
Dimensions: 6.8˝H x 5.8
˝W x 1.25˝D
Accessories: CH-6 Chassis; BB-2 Cabinet; BB-6 Cabinet
Wire Gauge: 12-18 AWG
Maximum IDC Wiring Resistance: 25 Ohms
External Power Supply Voltage: Regulated 24VDC
Ripple Voltage: 0.1 volts RMS maximum
IDC (supervised and power limited)
DC Voltage: 18-28 volts power limited
Frequency: DC
Current: 90mA per circuit
3825 Ohio Avenue, St. Charles, Illinois 60174
800/736-7672, FAX: 630/377-6495
www.systemsensor.com
DET. DETECTOR
MODEL COMP. ID MANUFACTURER BASE MODEL MAX DET.
1151 A SYSTEM SENSOR B110LP, B401 20
1451 A SYSTEM SENSOR B401, B401B 20
1451DH A SYSTEM SENSOR DH400 20
2151 A SYSTEM SENSOR B110LP, B401 20
2451 A SYSTEM SENSOR DH400, B401B, B401 20
2451TH A SYSTEM SENSOR B401, B401B 20
5451 A SYSTEM SENSOR B401 20
1100 A SYSTEM SENSOR N/A 20
1400 A SYSTEM SENSOR N/A 20
** 2100AT A SYSTEM SENSOR N/A 20
2100B A SYSTEM SENSOR N/A 20
2100D A SYSTEM SENSOR N/A 20
2100S A SYSTEM SENSOR N/A 20
2100TB A SYSTEM SENSOR N/A 20
2100TD A SYSTEM SENSOR N/A 20
2100TS A SYSTEM SENSOR N/A 20
2300B A SYSTEM SENSOR N/A 20
2300TB A SYSTEM SENSOR N/A 20
2400 A SYSTEM SENSOR N/A 20
2400TH A SYSTEM SENSOR N/A 20
* 2W-B A SYSTEM SENSOR N/A 20
* 2W-TB A SYSTEM SENSOR N/A 20
DH100LP A SYSTEM SENSOR N/A 20
* Class B, Style B only
** No Accessory will be supported by 2100AT
GENERAL DESCRIPTION
The CZ-6 Six Zone Interface Module is intended for use in an
intelligent alarm system. Each module provides an interface be-
tween the intelligent alarm system and a conventional alarm sys-
tem loop. A common SLC input is used for all modules, and the
initiating device loops share a common supervisory supply and
ground. Otherwise, each monitor operates independently from the
others. Each module has its own unique address.
A pair of rotary code switches is used to set the address of the first
module from 01 to 94. The remaining modules are automatically
assigned to the next five higher addresses. Provisions are included
for disabling a maximum of two unused modules to release the
addresses to be used elsewhere. Each module also has panel con-
trolled bicolor LED indicators. The panel can cause the LEDs to
blink, latch on, or latch off.
Compatible Two-wire System Sensor Smoke Detectors for use with CZ-6 with Zone Identifier A
I56-1799-005
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - SPECIFICATIONS

BEFORE INSTALLINGThis information is included as a quick reference installation guide. Refer to the appropriate control panel installation man

Seite 2 - Mounting

CabinetsA BB-6 cabinet will house the CH-6 chassis with up to six CZ-6 modules installed on it. Refer to cabinet installation documents for dime

Seite 3 - C0226-00

D500-49-00 3 I56-1799-005Step 1: Insert the bottom of the CZ-6 module down into a rear slot on the chassis. Step 2: Carefully swing th

Seite 4 - C0241-01

0123456789BASE ADDRESSTO NEXT DEVICE –STATUSINDICATORS— +— +— +— +— +— +INOUT+0+1+2+3+4+5IDCADDRESSIDCADDRESSIDCADDRESS— +

Seite 5 - C0242-00

System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for